C/A Design has air and liquid test stands available to simulate most avionics platforms. LabVIEW can also be used for data acquisition of thermal / fluid properties such as fluid temperatures, surface temperatures, power, flow and pressure in real time. Testing highlights include:
- Air to 100 CFM.
- Liquids to 10 GPM.
- -40° to 180° F Inlet fluid temperature range.
- 12 KW thermal loading.
- Coolanol 25R, water, ethylene glycol/water, polyalphaolefin (PAO), and air.
- Nitrogen Leak, Proof, & Burst Testing
- Pressure Drop Testing
- Varian Mass Spectrometer Leak Detector, up to X10-9 range
- LabVIEW Data Acquisition
|
 |
|